Water quality / NY / Rochester
City water report

Rochester, NY tap water quality.

City of Rochester Water Bureau has no open health-based violation in the records we checked. New York lists its January 2025 Lead and Copper Rule treatment-technique violation as corrective action taken. This report covers City of Rochester Water Bureau, which serves about 210,000 people using surface water; missing results are labeled rather than inferred.

Water system covered in this report
City of Rochester Water Bureau
System ID NY2704518
People served
210,000
Source water
surface water
Phone
585-428-6097

Your results at a glance.

Same four checks on every city page, always in the same order. Missing values are labeled, never guessed.

Health violations · 5 years
1
Resolved / archived records

Health-based limit-exceedance records since Oct. 2021; resolved or archived records are not presented as current.

Lead · 90th percentile
6.8 ppb
Below the 15 ppb action level

Period ending December 2025.

PFAS
Tested
Tested; no sampling-point-average screening flag

No detected PFAS rows in the UCMR 5 records for this system.

Hardness
Not reported
No measured value available

Hardness is not estimated from location.

The results, with context.

Each row identifies the result, its data period and its source. Missing measurements are not estimated.

ResultFinding / comparisonDate / periodSource
Lead and Copper RuleResolved — corrective action takenJanuary 2025EPA drinking-water data
Lead · 90th percentile6.8 ppb · Below the 15 ppb action levelDecember 2025EPA Lead & Copper data
PFASNo detected PFAS rows in these system records.UCMR 5 survey periodEPA UCMR 5
HardnessNot reported. Hardness is not estimated from location.Not reportedA utility report or water test is needed for a measured value.
General information, not a health or plumbing recommendation. EPA and utility records can update after this snapshot.
What this means for your home

Use the public-water result as a starting point.

City of Rochester Water Bureau did not trigger the lead or PFAS screening rules used for the headline. That does not mean every possible contaminant was tested or absent. For city water, treatment decisions can still depend on taste, disinfectant, plumbing, hardness and your own goals. The finder uses this report as a starting point, then asks about household flow and budget.

Next step

Add your home details.

Flow demand, plumbing, maintenance and budget can change which treatment fits even when two homes share the same utility.

Systems that fit this kind of water.

These are rule-based matches from the current FilterTier rankings. Size still depends on your home.

Aquasana HealthShield WH-HS
Best match

Aquasana HealthShield WH-HS

Current #1 on the city-water ranking. Exact-system health-effect reduction evidence is strong, but its 5.7 GPM certified/service flow makes household sizing important.

Trigger: Municipal-water profileCertified exact-system reduction claims5.7 GPM certified/service flowWaterScore 93 / 100
View system research →
iSpring WGB22B-PFKS PFAS + Heavy Metals
Also consider

iSpring WGB22B-PFKS PFAS + Heavy Metals

Current #2 on the city-water ranking. It offers much higher published flow, with verified exact-model PFAS/heavy-metal product data; confirm the exact certification evidence that matters to your goal.

Trigger: Municipal-water profileExact-model PFAS product data verifiedUp to 15 GPMWaterScore 94 / 100
View system research →

Ranking updates can change these matches. Evidence label and flow are shown so the tradeoff stays visible.

Rochester, New York — the city 2025 report and state correction record

Hemlock and Ontario supplies can mix; Rochester's lead records carry distinct dates and corrective-action status.

Rochester Water Bureau, NY2704518, draws from Hemlock and Canadice Lakes and also purchases Lake Ontario water from Monroe County Water Authority (MCWA). Some Rochester zones receive either source or a seasonal blend. Rochester also sells treated water wholesale to neighboring systems. The water bill and utility service map, not a ZIP match, determine the appropriate public-water-system and source context for a household.

Two source entries, not one citywide hardness or PFAS sample

The original 2025 municipal report issued in 2026 lists treatment-entry total hardness averaging 88 mg/L for Hemlock and 120 mg/L for Ontario. It records PFBA non-detected at Hemlock and 1 ng/L average at the Ontario entry (range ND–2 ng/L), alongside a PFOS non-detect at Hemlock and an Ontario ND–2.2 ng/L range. These are separate report-year entry-point observations, not a blend calculated for an individual house and not a current legal federal PFAS compliance ruling.

Lead 90th percentiles: the report table has a year-label conflict

The latest published 2025-report PDF includes a lead table labeled “2024 Surveys” with two separately shown 90th percentiles of 6.2 and 6.8 µg/L (ppb), from 101 and 118 sampled taps, respectively. The city's HTML rendition shows different older 8.9 and 9.0 µg/L values. The conflicting year labels and versions require reconciliation with NYSDOH monitoring dates before assigning the 6.2/6.8 values to a specific 2025 sampling half-year. Do not conflate a 21.6 ppb individual tap maximum with the system 90th percentile or any home's result.

April 2025 treatment-technique finding and NYSDOH status

The utility reports that NYSDOH revoked a historical optimal corrosion-control approval in April 2025 and issued a Lead and Copper Rule treatment-related violation. Separately, New York State's 2025 Monroe County official compliance report lists Rochester City NY2704518, January violation code 58 — OCCT/SOWT installation demonstration, with status “Corrective action taken.” The state's recorded corrective action must not be presented as an active untreated November 2026 emergency, nor as proof that all future corrosion-control installation or formal federal case closure was completed. The regulatory treatment finding is distinct from an exceedance of sampled lead's action-level percentile.

Rochester reports 2,076 lead-containing water services replaced in 2025, without proving the material of any customer's private interior pipes. For household interpretation use the city's property information/lead service-line inventory and water lab. A 2025 annual report is not a real-time address-specific test.

Original May 2026 PDF pages 10, 12, 14 and 18 visually reviewed November 9, 2026; the 2025-report lead table is labeled 2024 despite changed numbers versus HTML. NYSDOH's 2025 violation status is “Corrective action taken,” while any later 2026 action or federal SDWIS closure needs direct confirmation. No fabricated lead dates, full current PFAS compliance or individual address matching.

Beyond the city boundary

Areas served & connected communities.

A utility service area is not the same as a city boundary. Service-area maps can be approximate; confirm your provider on your bill.

Service-area matches

Communities in this utility’s mapped area

Ask your provider about nearby communities and address-specific service coverage.

Same reported system ID

Other city reports for this utility

A shared system ID connects the reports, but does not mean every tap has identical water quality.

See the utility’s service-area map for coverage beyond this city.

Sources: EPA service-area boundaries. Maps can be approximate and are not a guarantee of service at an address.
Water supply relationships

Where the utility fits in the supply network.

Reported wholesale relationships may be seasonal, backup or partial supplies. They do not establish today’s water blend, treatment or an identical contaminant profile.

Reported suppliers

Water supplied by

Utility in this reportCity of Rochester Water BureauNY2704518
Reported recipients

Supplies water to

Source: EPA SDWA utility relationship data. Verify current arrangements with the utilities.
City-level context, not a home test

What local housing can—and cannot—tell you.

Housing estimates describe Rochester, not the materials, water quality or plumbing demand of your individual home.

Homes built before 198087%

Housing age does not confirm lead plumbing.

Owner-occupied homes38%

Tenure is context, not a treatment requirement.

Median rooms per home5.1

Room count does not determine peak flow.

Source: 2020–2024 ACS five-year estimates. These are population estimates, not property-level measurements. Check your service-line materials and actual simultaneous fixtures rather than choosing treatment from city averages.

Live air-quality map · Rochester, NY

Explore the latest available outdoor air readings from AirNow. Credit: U.S. EPA AirNow and participating state, local and tribal air agencies. Live observations are preliminary and may change after quality assurance; they are not regulatory compliance determinations. Observation times are shown in the map. Missing readings do not mean clean air.

Open the live AirNow map ↗

For validated regulatory air-quality data and trend analysis, use EPA AirData/AQS.

Questions about Rochester water.

Which water utility serves Rochester?

The water system covered in this report is City of Rochester Water Bureau (system ID NY2704518), serving about 210,000 people. If your bill shows another utility, use the ZIP report to confirm your system.

Was lead reported for Rochester?

The latest 90th-percentile result in this dataset is 6.8 ppb for the period ending December 2025. Lead can also come from building plumbing, so utility results do not describe every tap.

What does the PFAS result mean?

PFAS was included in the national survey data used here and no sampling-point average in the city index triggered the screening flag.

Do I need a whole-house filter?

Not automatically. The right treatment depends on the exact contaminants, your plumbing, household flow, maintenance preference and budget. Use the finder to combine this public-water profile with your home details.

Does one utility serve every address in Rochester?

Service boundaries can cross city limits, and a city may have more than one provider. Match the utility and system ID to your water bill before applying a public-water result to your address. Private wells need their own testing.

Sources and update date.

EPA drinking-water database

Utility identity, system ID, source-water context, violations and Lead & Copper results. For lead, the 15 ppb action level remains the applicable transition-period threshold until LCRI compliance begins November 1, 2027; FilterTier uses 10 ppb as a screening flag on these city pages.

EPA UCMR 5

National PFAS survey data used for the city screening rule. Survey data does not by itself establish MCL compliance. As of October 2026, PFOA/PFOS MCLs remain in force; EPA has separately proposed an optional compliance extension and proposed rescinding the PFHxS, PFNA, HFPO-DA and hazard-index provisions.

About this water system

Match the provider and system ID to your water bill. Data snapshot: EPA SDWA 2026Q2 / UCMR 5 August 2026 final.

Official utility / regulatory source

Official 2025 City of Rochester Water Bureau report explicitly lists Water Supply ID NY2704518. Previously flagged 2025 lead/copper treatment-technique item was separately verified as corrective action taken.

Not your city?

Check your ZIP code.

Find the public water systems mapped to your ZIP and choose the one on your bill.

See my water report