Water quality / CA / Santa Ana
City water report

Santa Ana, CA tap water quality.

At least one sampling point averaged above an EPA PFAS limit in EPA's national PFAS survey. This is a screening result, not a violation. The strongest city-index PFAS flag is PFOS, at 3.4× the screening comparison. EPA evaluates PFAS compliance using running annual averages, so FilterTier labels this a screening result rather than a violation.

Water system covered in this report
City of Santa Ana
System ID CA3010038
People served
310,539
Source water
surface water
Phone
714-647-3387

Your results at a glance.

Same four checks on every city page, always in the same order. Missing values are labeled, never guessed.

Health violations · 5 years
0
No health-based flag found

Health-based limit-exceedance records since Oct. 2021; resolved or archived records are not presented as current.

Lead · 90th percentile
0 ppb
Below the 15 ppb action level

Period ending December 2024.

PFAS
5 detected
Screening flag

Detected examples: PFOS, PFOA, PFHxS, PFPeA….

Hardness
Not reported
No measured value available

Hardness is not estimated from location.

The results, with context.

Each row identifies the result, its data period and its source. Missing measurements are not estimated.

ResultFinding / comparisonDate / periodSource
Health-based violationsNo health-based limit-exceedance flag in these water-system records.Since Oct. 2021EPA drinking-water data
Lead · 90th percentile0 ppb · Below the 15 ppb action levelDecember 2024EPA Lead & Copper data
PFOSHighest single sample 14.2 ng/L · EPA MCL 4 ng/L
Single-sample values are context only; EPA PFAS compliance is based on running annual averages.
UCMR 5 survey periodEPA UCMR 5
PFOAHighest single sample 8.9 ng/L · EPA MCL 4 ng/L
Single-sample values are context only; EPA PFAS compliance is based on running annual averages.
UCMR 5 survey periodEPA UCMR 5
PFHxSHighest single sample 8.4 ng/L · EPA MCL 10 ng/L
Single-sample values are context only; EPA PFAS compliance is based on running annual averages.
UCMR 5 survey periodEPA UCMR 5
PFPeAHighest single sample 5.9 ng/L · No individual federal MCL shown for this compound
Single-sample values are context only; EPA PFAS compliance is based on running annual averages.
UCMR 5 survey periodEPA UCMR 5
PFHxAHighest single sample 4 ng/L · No individual federal MCL shown for this compound
Single-sample values are context only; EPA PFAS compliance is based on running annual averages.
UCMR 5 survey periodEPA UCMR 5
LithiumHighest reported UCMR 5 result: 42.4 µg/L · monitoring result, not presented as a violationUCMR 5 survey periodEPA UCMR 5
HardnessNot reported. Hardness is not estimated from location.Not reportedA utility report or water test is needed for a measured value.
General information, not a health or plumbing recommendation. EPA and utility records can update after this snapshot.
What this means for your home

Use the public-water result as a starting point.

PFAS is the main screening flag in this report. At least one sampling point averaged above the comparison level used for PFOS in EPA's national survey. EPA evaluates compliance using annual averages, so FilterTier does not call this a violation. If PFAS is your priority, favor exact-system certification and then check whether the certified flow can support your home.

Next step

Add your home details.

Flow demand, plumbing, maintenance and budget can change which treatment fits even when two homes share the same utility.

Systems that fit this kind of water.

These are rule-based matches from the current FilterTier rankings. Size still depends on your home.

Aquasana HealthShield WH-HS
Best match

Aquasana HealthShield WH-HS

Matched because this city report has a PFAS screening flag and this is the current #1 PFAS-ranked exact system with documented reduction evidence.

Trigger: PFAS screening flagCertified exact-system reduction claims5.7 GPM certified/service flowWaterScore 93 / 100
View system research →
iSpring WGB22B-PFKS PFAS + Heavy Metals
Also consider

iSpring WGB22B-PFKS PFAS + Heavy Metals

Current #2 PFAS-ranked system. Its exact-model PFAS product specifications and flow are verified; confirm the certification evidence that matters to your goal before buying.

Trigger: PFAS screening flagExact-model PFAS product data verifiedUp to 15 GPMWaterScore 94 / 100
View system research →

Ranking updates can change these matches. Evidence label and flow are shown so the tradeoff stays visible.

Santa Ana, California — actual 2025 utility report and 2024 lead testing

Santa Ana's city report distinguishes groundwater, imported supplies, and tap-sample dates.

California's drinking-water regulator identifies the active City of Santa Ana utility, CA3010038. The city's original 2025 report describes an approximately 85% local groundwater and 15% Metropolitan Water District imported-water annual supply mix, with water sources sampled and presented in separate tables. Those utility-wide annual proportions do not establish the blend or quality at an individual house. Check the utility on your bill and any address-specific notices.

Lead: the tap-sampling year was 2024, not 2025

In the 2025-published results table, Santa Ana says that 66 residences were sampled for lead in 2024. The 90th percentile was non-detect (ND), with 0 of 66 over the report's then-applicable 15 parts-per-billion action level. The California database rounds the same monitoring-period result to 0 mg/L; ND and a rounded regulatory summary are not proof that all household taps contain no lead. Lead can come from a home's own plumbing.

Groundwater hardness is not a blended tap measurement

The city's original 2025 groundwater table reports total hardness averaging 239 mg/L as CaCO3 (14 grains per gallon), with 130–307 mg/L observed. These measurements are for municipal groundwater; imported water is tabulated separately and individual customer supply blends can vary. Do not use 239 mg/L as an address-specific whole-home hardness laboratory result.

PFAS: different monitoring points, not a confirmed MCL violation

The city's 2025 distribution entry-point monitoring table reports PFOS 4.2 ppt average (ND–14 ppt) and PFOA 2.7 ppt average (ND–8.9 ppt). The separately presented 2025 groundwater PFOS row reports an average of 4 ppt (ND–18 ppt). A maximum individual detection, source-specific average, and regulatory compliance-point running annual average are different things. None of these table rows alone establishes a 2026 PFAS MCL violation. The report also notes California PFAS notification-level revisions effective October 29, 2025.

Original 2025 city report and official tables visually verified November 9, 2026. Lead is from 2024 sampling (66 households); hardness is specifically 2025 groundwater; PFAS is 2025 monitoring from different entry/source points. ND is not numeric zero. Current address/ZIP retail coverage and active/closed state enforcement status remain to be confirmed. The underlying EPA SDWA/UCMR5 data are unchanged.

Beyond the city boundary

Areas served & connected communities.

A utility service area is not the same as a city boundary. Service-area maps can be approximate; confirm your provider on your bill.

Service-area matches

Communities in this utility’s mapped area

Ask your provider about nearby communities and address-specific service coverage.

Same reported system ID

Other city reports for this utility

A shared system ID connects the reports, but does not mean every tap has identical water quality.

See the utility’s service-area map for coverage beyond this city.

Sources: EPA service-area boundaries. Maps can be approximate and are not a guarantee of service at an address.
Water supply relationships

Where the utility fits in the supply network.

Reported wholesale relationships may be seasonal, backup or partial supplies. They do not establish today’s water blend, treatment or an identical contaminant profile.

Utility in this reportCity of Santa AnaCA3010038
Reported recipients

Supplies water to

Source: EPA SDWA utility relationship data. Verify current arrangements with the utilities.
City-level context, not a home test

What local housing can—and cannot—tell you.

Housing estimates describe Santa Ana, not the materials, water quality or plumbing demand of your individual home.

Homes built before 198074%

Housing age does not confirm lead plumbing.

Owner-occupied homes45%

Tenure is context, not a treatment requirement.

Median rooms per home4.4

Room count does not determine peak flow.

Source: 2020–2024 ACS five-year estimates. These are population estimates, not property-level measurements. Check your service-line materials and actual simultaneous fixtures rather than choosing treatment from city averages.

Live air-quality map · Santa Ana, CA

Explore the latest available outdoor air readings from AirNow. Credit: U.S. EPA AirNow and participating state, local and tribal air agencies. Live observations are preliminary and may change after quality assurance; they are not regulatory compliance determinations. Observation times are shown in the map. Missing readings do not mean clean air.

Open the live AirNow map ↗

For validated regulatory air-quality data and trend analysis, use EPA AirData/AQS.

Questions about Santa Ana water.

Which water utility serves Santa Ana?

The water system covered in this report is City of Santa Ana (system ID CA3010038), serving about 310,539 people. If your bill shows another utility, use the ZIP report to confirm your system.

Was lead reported for Santa Ana?

The latest 90th-percentile result in this dataset is 0 ppb for the period ending December 2024. Lead can also come from building plumbing, so utility results do not describe every tap.

What does the PFAS result mean?

At least one sampling point averaged above the screening comparison used by FilterTier for PFOS. EPA evaluates compliance using annual averages; this city-page result is a screening flag, not a violation.

Do I need a whole-house filter?

Not automatically. The right treatment depends on the exact contaminants, your plumbing, household flow, maintenance preference and budget. Use the finder to combine this public-water profile with your home details.

Does one utility serve every address in Santa Ana?

Service boundaries can cross city limits, and a city may have more than one provider. Match the utility and system ID to your water bill before applying a public-water result to your address. Private wells need their own testing.

Sources and update date.

EPA drinking-water database

Utility identity, system ID, source-water context, violations and Lead & Copper results. For lead, the 15 ppb action level remains the applicable transition-period threshold until LCRI compliance begins November 1, 2027; FilterTier uses 10 ppb as a screening flag on these city pages.

EPA UCMR 5

National PFAS survey data used for the city screening rule. Survey data does not by itself establish MCL compliance. As of October 2026, PFOA/PFOS MCLs remain in force; EPA has separately proposed an optional compliance extension and proposed rescinding the PFHxS, PFNA, HFPO-DA and hazard-index provisions.

About this water system

Match the provider and system ID to your water bill. Data snapshot: EPA SDWA 2026Q2 / UCMR 5 August 2026 final.

Official utility / regulatory source

California Drinking Water Watch identifies CA3010038 as CITY OF SANTA ANA, active community system with purchased surface water.

Not your city?

Check your ZIP code.

Find the public water systems mapped to your ZIP and choose the one on your bill.

See my water report